Maintenance Object Repair Procedures
Table 10-68. System Technician-Demanded Tests: ATM-BCH
Order of Investigation
Signaling Link State Check Test (#255)
Service State Audit Test (#256)
Call State Audit Test (#257)
ISDN Test Call Test (#258)
Signaling Link State Audit Test (#255)
This non-destructive test checks the status of the TN230x ATM-CES Interface
circuit pack and the ATM D-channel (ATM-DCH) trunk, which are both important
elements to the health of the ATM-BCH trunk.
Table 10-69. TEST #255 Signaling Link State Audit Test
Error
Code
Result
None
ABORT
0
ABORT
1114
ABORT
1018
ABORT
4
FAIL
8
FAIL
PASS
10-200
Issue 4 May 2002
Test
Internal system error
Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
Maintenance disabled
1. Enable maintenance. Enter y in the Maintenance Tests?
field on page 2 of the change trunk-group form.
Signaling channel problem
1. Look for errors or alarms against the
Signaling Group)''
maintenance objects.
TN230x circuit pack failed
1. See the
''ATM-INTF (TN2305/6)''
Signaling link OK.
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
Continued on next page
Description/Recommendation
''ATM-SGRP (ATM
and
''ATM-DCH (ATM D-Channel Port)''
maintenance object.
Continued on next page
Destructive or
Non-destructive
ND
ND
ND
ND
555-233-123