Avaya Definity SI Maintenance Manual page 1610

Table of Contents

Advertisement

Maintenance Object Repair Procedures
External Device Alarm Test (#120)
The External Device Alarm Test requests the state of the External Device Alarm
from a Maintenance circuit pack and reports the results. The test has no effect on
the external device itself.
Table 10-301. TEST #120 External Device Alarm Test
Error
Code
1000
1035
2000
10-824
Issue 4 May 2002
Test
Result
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
The Expansion Port Network containing this equipment is not
available
Look for and resolve all Expansion Port Network problems
with this cabinet.
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. (Maintenance Board) If the test continues to ABORT with
error code 2000, check for system powering problems
with the A carrier. Look for and resolve all AC-POWER
and CARR-POW alarms in a multicarrier cabinet or
DC-POWER alarms in a single carrier cabinet. Then,
repeat the test.
3. (Maintenance Board) If the test continues to ABORT with
a 2000 error code, check for and resolve all maintenance
circuit pack errors. Then, repeat the test.
4. If the test continues to ABORT with a 2000 error code,
then escalate the problem.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading

Table of Contents