Avaya Definity SI Maintenance Manual page 1071

Table of Contents

Advertisement

BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Table 10-113. TEST #621 Level 1 Status Inquiry — Continued
Error
Code
2
555-233-123
Test
Result
FAIL
For the TN556 or TN2208, received a status of Level 1
Pending Activation-Endpoint Active which indicates a problem
with the BRI endpoint or ASAI or Avaya adjunct, the wiring to
the endpoint or adjunct, or the ISDN-BRI port.
For the TN2198, received a status of Level 1 Pending
Activation. U interface up S/T interface down, which indicates
a problem with the NT1 or the wiring between the NT1 and the
BRI endpoint (S/T interface).
1. As necessary, check and repair the wiring between the
circuit pack and the endpoint or adjunct. Execute the test
port PCSSpp command, and review the results of the
Level 1 Status Inquiry test to verify the repair. If this test is
still failing, proceed to Step 2.
2. For BRI endpoints, try replacing the BRI endpoint(s)
connected to the port. For ASAI or Avaya adjuncts, follow
the recommended repair procedures of the manufacturer
for link communication problems. For the NT1, follow the
recommended repair procedures of the manufacturer.
Then execute the test port PCSSpp command, and
review the results of the Level 1 Status Inquiry test to
verify repair. If this test is still failing, proceed to Step 3.
3. Escalate the problem to the next tier.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-285