ANL-16-L (16-Port Neon Analog Line)
Table 10-28. TEST #36 Station Status and Translation Audits and Updates Test
Error
Code
5
7
8
0
555-233-123
— Continued
Test
Result
FAIL
This does not indicate a hardware problem. However, there
may be an internal software error. The message waiting lamp
update failed. The translation and ringer updates were not
performed because of this failure.
FAIL
The translation update failed. This does not indicate a
hardware problem. However, there may be an internal
software error. The ringer update was not performed because
of this failure.
FAIL
This does not indicate a hardware problem. However, there
may be an internal software error. The ringer update failed.
1. Retry the command at 1-minute intervals a maximum of
5 times.
PASS
The software and the port processor have the same status.
User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by
examining the station.
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems
that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure
that there is a valid board inserted.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-77