DIG-LINE (Digital Line)
Table 10-215. TEST #16 DIG-LINE Station Lamp Updates Test — Continued
Error
Code
1392
Digital Station Audits Test (#17)
This is a series of six tests which are classified as audits. The SPE sends
messages to the on-board microprocessor to perform the following tests. These
audits run only if the station is in-service.
Switchhook Inquiry Test
to the circuit pack's records. This inquiry is sent all the way to the voice
terminal.
Bad Scan Inquiry Test
that is generated due to certain events relating to the link conditions. This
can be an indication of communications problems between the Processor
and Digital Port circuit pack.
555-233-123
Test
Result
ABORT
This port is currently a TTI port and the test will not execute on
it.
1. Verify that the port is a TTI port using either the display
port command (the display shows that the port is a TTI
port) or the list config command (the display shows a t for
the port).
2. If either list config or display port indicates that the port is
not a TTI port, escalate the problem. If both commands
indicate that the port is a TTI port, the abort is correct, and
no action is necessary.
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
The message to light all of the station lamps was sent
successfully to the port.
1. Observe the station lamps being lit when running the test. If
all lamps do not light successfully, the other Digital Line
test results may indicate related problems that will not
allow the lamps to light.
2. Investigate by using other Digital Line port tests, and by
examining the station, wiring, and connections.
This is an update of the SPE records according
A message is sent uplink which contains a count
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-581