Avaya Definity SI Maintenance Manual page 736

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids
Output
The following screen is an example of the output from the test station 81902
short command with the assumptions that port in cabinet 1, carrier c, slot 7, circuit
1 is an analog port and extension 81902 is connected to that port. The responses
display on a test-by-test basis with one line of data for each test result.
test station 81902 short
Port
Maintenance Name
01C0701
ANL-LINE
01C0701
ANL-LINE
01C0701
ANL-LINE
Command Successfully Completed
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No
Result
Error Code
8-486
Issue 4 May 2002
TEST RESULTS
Alt. Name Test No. Result
35
48
36
The port address: cabinet-carrier-slot-circuit
The type of maintenance object that is being tested.
Alternate means of identifying the maintenance object. This
field contains the extension when the object is a station.
Test being executed
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Numeric code explaining why the release failed or aborted.
Refer to the list of codes by test number for each MO.
Error Code
PASS
PASS
PASS