Avaya Definity SI Maintenance Manual page 688

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids
Output
The following screen shows the output for test environment 1 to test a MCC/PPN
cabinet. The responses appear on a test-by-test basis with one line of data for
each test result.
test environment 1
Port
Maintenance Name
01
POWER
01
AC-POWER
01A
CARR-POW
01B
CARR-POW
01C
CARR-POW
01D
CARR-POW
01E
CARR-POW
01
EMG-XFER
01
CABINET
01
EXT-DEV
01
RING-GEN
Command Successfully Completed
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No.
Result
Error Code
8-438
Issue 4 May 2002
TEST RESULTS
Alt. Name Test No. Result
5
79
127
127
127
127
127
124
122
120
118
Port address (cabinet-carrier). For all but the CARR-POW
maintenance object, only the cabinet value is displayed. For the
CARR-POW maintenance object, both the cabinet and carrier
values display.
The name of maintenance object
Not applicable
The test being executed.
Test result: Pass, Abort, Fail, Disabled
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
Error Code
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
555-233-123