Maintenance Object Repair Procedures
Table 10-225. TEST #6 NPE Crosstalk Test — Continued
Error
Code
1003
1004
2000
2100
Any
10-604
Issue 4 May 2002
Test
Result
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at one-minute
intervals a maximum of 5 times.
ABORT
The port was seized by a valid call during the test. The test has
been aborted. Use the display port PCSSpp command to
determine the trunk group/member number of the port. Use the
status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
FAIL
The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external
wiring.