Avaya Definity SI Maintenance Manual page 1096

Table of Contents

Advertisement

Maintenance Object Repair Procedures
This test is not executed for ASAI adjuncts because adjuncts do not support MIMs
upon which this test is based.
Table 10-123. TEST #627 BRI Remote Loop Back
Error
Code
1000
1005
1113
1139
1141
1144
10-310
Issue 4 May 2002
Test
Result
ABORT
Could not seize the endpoint or B-channels for test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
The endpoint's MIMs Supported field is administered to "no."
1. Use the change station extension command to change
parameter only if the endpoint documentation reflects
support for ISDN-BRI Management and Maintenance
Procedures.
ABORT
The signaling link between the switch and the endpoint is
down.
1. Use the test port PCSSpp long command to clear any
errors which prevent establishment of the signaling link.
2. Examine the results of the Signaling Link Status Test
(#626) which is run as part of this command. If this test
aborts or fails, follow the repair procedure for Test #626.
3. If the XID Test #628 continues to abort, escalate the
problem.
ABORT
The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
ABORT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack)
Maintenance documentation.
2. If Step 1 does not resolve the problem, escalate to the
next tier.
ABORT
The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the
PPN.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading

Table of Contents