ETH-PT (Control LAN Ethernet)
h. Error Type 3329: TCP/IP Ping Test failed.
1. Test port (test port UUCSSpp short).
2. Refer to TCP/IP Ping Test (#1281) repair procedures.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors in the order they appear in the table below.
Table 10-279. System Technician-Demanded Tests: ETH-PT
Order of Investigation
Ethernet Local Loop-Around Test (#1278)
TCP/IP Ping Test (#1281)
Session Status Test (#1286)
Link Integrity Inquiry Test (#1282)
1
D = Destructive, ND = Non-destructive
555-233-123
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
Issue 4 May 2002
1
D/ND
D
ND
ND
ND