Avaya Definity SI Maintenance Manual page 1100

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-124. TEST #628 BRI XID — Continued
Error
Code
1141
1144
1187
10-314
Issue 4 May 2002
Test
Result
ABORT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack)
Maintenance documentation.
2. If Step 1 does not resolve the problem, escalate to the
next tier.
ABORT
The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the
PPN.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
ABORT
The circuit pack, port or station may have been busied out by a
technician.
1. Look in the Error Log for Error Type 18 (busied out) for
BRI-BD, BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release
the station via the release station command.
a. If this error type is present for BRI-PORT and BRI-SET,
then release the port via release port PCSSpp
command and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and
BRI-SET, then release the circuit pack via the release
port PCSSpp command and run the test again. If the
error is present for BRI-SET only, then release the
circuit pack via the release port PCSSpp command
and run the test again. If the error is present for both
BRI-BD and BRI-PORT, then release the circuit pack
via the release board PPCSS command and run the
test again.
NOTE:
When you release the circuit pack, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading

Table of Contents