Maintenance Object Repair Procedures
Table 10-134. TEST #693 Memory Card Erase/Write/Read Test
Error
Code
1192
ABORT
2012
ABORT
2106
2114
2013
ABORT
2100
none
2110
ABORT
2111
ABORT
2112
ABORT
2113
ABORT
10-350
Issue 4 May 2002
Test
Result
Applications are accessing the memory card.
1. Wait 10 minutes for the applications to complete.
2. Retry the command at 1-minute intervals, up to 5 times.
3. If the problem persists, escalate the problem.
Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
Memory card not present.
Switch does not recognize the memory card.
1. Insert a formatted memory card into the slot at the
TN2401/TN794 NetPkt or TN777B Netcon circuit pack.
2. Retry the command at 1-minute intervals, up to 5 times.
3. If the problem persists, escalate the problem.
Memory card is a system-upgrade memory card.
1. Replace the inserted memory card with a user's memory
card.
2. Retry the command at 1-minute intervals, up to 5 times.
3. If the problem persists, escalate the problem.
Memory card has only one directory file.
1. Verify the Memory Card Directory Recovery Test (#699)
result (test card-mem).
2. If the problem persists, replace the memory card.
3. Retry the command at 1-minute intervals, up to 5 times.
4. If the problem persists, escalate the problem.
Description/Recommendation
Continued on next page