Maintenance Object Repair Procedures
Table 10-273. TEST #16 DIG-LINE Station Lamp Updates Test — Continued
Error
Code
1392
10-732
Issue 4 May 2002
Test
Result
ABORT
This is currently a TTI port, and the test cannot execute on it.
1. Verify that the port is a TTI port using either the display
port command (the display shows that the port is a TTI
port) or the list config command (the display shows a t for
the port).
2. If either list config or display port indicates that the port is
not a TTI port, escalate the problem. If both commands
indicate that the port is a TTI port, the abort is correct, and
no action is necessary.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
The message to light all of the station lamps was sent
successfully to the port.
1. Observe the station lamps being lit when running the test. If
all lamps do not light successfully, the other Digital Line
test results may indicate related problems that will not
allow the lamps to light.
2. Investigate by using other Digital Line port tests and by
examining the station, wiring, and connections.
Description/Recommendation