Maintenance Object Repair Procedures
Table 10-56. ASAI-EPT Error Log Entries — Continued
Error
Aux
Type
Data
2568 (i)
0
3329 (j)
Any
3584-
0, 1
3839 (k)
3841 (l)
0
4095
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol.
Timers associated with certain Layer 3 messages have expired before a
required response was received. In the following table, the aux data
column indicates which timer has just expired. For more information, refer
to the Avaya ISDN-BRI Specification.
Aux Data
The switch sent a message to an endpoint that did not respond in the
allotted time. This may be due to failure of the point-to-point signaling link
or because of a problem in the ASAI adjunct. To repair:
10-174
Issue 4 May 2002
Associated Test
ASAI-EPT
None
Signaling Link
MAJ/WNG
Status (626)
None
None
2
First T303 (SETUP timer)
3
Second T303 (SETUP timer)
4
T305 (DISConnect timer)
5
First T308 (RELease timer)
6
Second T308 (RELease timer)
10
T316 (RESTart timer)
12
T309 (Layer 2 Failure timer)
16
TM100 (Management Information Message timer 1)
17
TM200 (Management Information Message timer 2)
102
TASAI (ASAI Routing Timer)
Execute the test station extension command and perform the
associated repair procedures for those tests.
Alarm
On/
Level
Off
Board
OFF
Timer Type
Test to Clear Value
Continued on next page