Maintenance Object Repair Procedures
Table 10-212. TEST #9 Digital Line NPE Crosstalk Test — Continued
Error
Code
1002
1003
1004
10-574
Issue 4 May 2002
Test
Result
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
ABORT
The port was seized by a valid call during the test. The test has
been aborted. Use display port PCSSpp to determine the
station extension or attendant number of the port. Use status
station or status attendant to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not
busied out.
Description/Recommendation
Continued on next page
555-233-123