Avaya Definity SI Maintenance Manual page 1292

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Value
Table 10-185. Data Line Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1
Digital Loop Around
Test (#171)
15(a)
Any
Audit Update Test
(#36)
18
0
busyout port PCSSpp
130 (b)
None
257
Conference Circuit
Test (#7)
513
NPE Crosstalk Test
(#6)
769(a)
Any (c)
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. This error is logged when the Data Line circuit pack finds an error with the
transmit/receive circuitry of an administered Data Line on circuit pack
insertion. Perform the following procedure:
1. Issue the busyout board PCSS command to busyout the Data Line
2. Issue the reset board PCSS command. Check the Hardware Error
3. Issue the release board PCSS command to release the Data Line
10-506
Issue 4 May 2002
Associated Test
Alarm Level
Any
MINOR
WARNING
WARNING
MINOR
MINOR
circuit pack on which this port resides.
Log to determine if Error Type 769 is logged again for the DAT-LINE
MO.
NOTE:
When displaying errors, set the Active Alarms Only field to "n."
If Error Type 769 reappears, replace the DAT-LINE circuit pack. If
Error Type 769 does not reappear, proceed to Step 3.
circuit pack on which this port resides.
On/Off
Board
Test to Clear Value
Any
test port PCSSpp sh r 1
ON
test port PCSSpp sh r 2
OFF
release port PCSSpp
ON
test port PCSSpp sh
ON
test port PCSSpp l r 2
ON
test port PCSSpp l r 2
555-233-123

Advertisement

Table of Contents
loading

Table of Contents