EXP-INTF (Expansion Interface Circuit Pack)
e. Error Type 257 with Aux Data 85 through 88 indicates that this EI circuit
pack is detecting incorrect data on the incoming fiber bit stream. The data
is originating at the opposite EI circuit pack. These errors could result from
a bad timing reference on the network which contains the EI circuit pack on
the opposite end of the fiber. For example, if the error is logged against the
1B01 (PPN) EI circuit pack, then the bad timing reference is on the EPN.
Resolve any EXP-INTF errors 2305, 769, or 770. Resolve any TONE-BD,
TDM-CLK, or SYNC errors. Finally, if the errors continue to occur, perform
the following procedure:
1. If the EI circuit pack reporting the error is part of the Active link and a
2. Reset the EI circuit pack at the opposite end of fiber.
3. Issue the test board PCSS repeat 10 command, where PCSS is
4. Wait 15 minutes. Then check the Error Log to see if new errors of
5. If errors are present, reset the EI circuit pack reporting the errors.
6. Wait five minutes. Then check the Error Log to see if new errors of
7. If errors are present, replace the EI circuit pack or transceiver at the
8. Wait 15 minutes. Then check the Error Log to see if new errors of
9. If errors are present or if this error occurs intermittently (over one
f. Error Type 513 with Aux Data 5 through 7 indicates an ON BOARD
hardware failure of the circuit packs RAM or ROM. Replace the EI circuit
pack or transceiver.
g. Error Type 1538 indicates a hyperactive EI circuit pack that is generating
an abnormal amount of control messages to the Processor circuit pack.
When this error was generated, the EI was automatically reset by the
system. If this system does not have duplicate EI Links, service to the EPN
is disrupted. If this system does have duplicate EI Links, the system should
have switched to the Standby EI Link. Reset the EI. If error 1538 is
detected again, replace the EI circuit pack or transceiver.
h. Error Type 2049 indicates that the last time the EI circuit pack was reset, its
initialization tests failed. The number in the Aux Data field is the error code
with which Reset Test (#336) failed. Follow the procedure specified in the
Reset Test (#336) FAIL section for this error code.
555-233-123
Standby link exists, switch to the Standby link.
the address of the EXP-INTF circuit pack reporting the error. If Tests
#241 or #316 fail even once, follow the procedures associated with
the failures.
type 257 have been detected.
type 257 have been detected.
opposite end of the fiber.
type 257 have been detected.
week's time), replace the EI circuit packs or transceivers on this link.
Issue 4 May 2002
10-773