Maintenance Object Repair Procedures
Table 10-162. TEST #314 DS1CO Dial Tone Seizure Test — Continued
Error
Code
1005
1018
1020
1040
2000
2012
2100
10-434
Issue 4 May 2002
Test
Result
ABORT
Test failed due to incompatible configuration administered in
trunk group form.
1. Verify the following fields on the trunk group administration
screen: Is trunk direction incoming only? Is trunk the port
24 of the DS1 Interface circuit pack while common control
channel signaling is specified? Is trunk group type the
automatic CO (for example, FX)?
2. If the trunk has been administered using the above
information, then this test should abort.
ABORT
The test is disabled via translation. You may want to determine
why the test has been disabled before you enable it.
1. Verify that the 'Maintenance Test' field on the 'Trunk Group'
form is set to 'n'. To enable the test, issue the change
trunk-group x command (x equals the number of the
trunk group to be tested). Then, change the entry in the
'Maintenance Test' field on the form to 'y'.
2. Repeat the test.
ABORT
The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in the Hardware Error Log. If
present, refer to DS1-BD (DS1 Trunk Circuit Pack)
Maintenance documentation.
2. Retry the command.
ABORT
The test was aborted because this port may be an access
endpoint.
1. Verify that this port is an access endpoint by issuing the
display port command.
2. If the port has been administered as an access endpoint,
then this is a normal abort.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
The test was aborted due to an internal system error.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
Description/Recommendation
Continued on next page