Maintenance Object Repair Procedures
Table 10-167. TEST #6 NPE Crosstalk Test — Continued
Error
Code
1004
2000
2100
Any
0
10-454
Issue 4 May 2002
Test
Result
ABORT
The port was seized by a valid call during the test. The test has
been aborted. Use the display port PCSSpp command to
determine the trunk group/member number of the port. Use
the status trunk command to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids", for a full description of
all possible states.) You must wait until the port is idle before
retesting.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external
wiring.
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Check to ensure that the board translations are correct.
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish
the linkage between the internal ID and the port.
Description/Recommendation
Continued on next page