Avaya Definity SI Maintenance Manual page 1106

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-126. TEST #630 BRI Set Audits — Continued
Error
Code
1187
2012
2100
10-320
Issue 4 May 2002
Test
Result
ABORT
The circuit pack, port or station may have been busied out by
a technician.
1. Look in the Error Log for Error Type 18 (busied out) for
BRI-BD, BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release
the station via the release station command.
a. If this error type is present for BRI-PORT and BRI-SET,
then release the port via the release port PCSSpp
command and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and
BRI-SET, then release the circuit pack via the release
port PCSSpp command and run the test again. If the
error is present for both BRI-BD and BRI-PORT, then
release the circuit pack via the release board PPCSS
command and run the test again.
NOTE:
When you release the circuit pack, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
Internal System Error.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page