Maintenance Object Repair Procedures
Table 10-252. TEST #1227 ICSU Status LEDs Test — Continued
Error
Code
Result
2500
ABORT
PASS
0
NO
BOARD
10-694
Issue 4 May 2002
Test
Internal system error.
1. Retry the command.
The ICSU Status LEDs test executed successfully. A PASS
result, however, does not necessarily mean that the status LEDs
behaved properly. It only means that the software successfully
attempted to light the status LEDs. This is a visual test. The
service technician must visually exam the behavior of the LEDs
while the test is running. The LEDs are functioning properly if the
four status LEDs are lit red for 5 seconds, then lit green for 5
seconds, then lit yellow for 5 seconds. If the LEDs behave
differently, escalate this problem.
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use
the add ds1 UUCSS command to administer the DS1
interface if it is not already administered.
2. If board was already administered correctly, check the error
log to determine if the board is hyperactive. If this is the case,
the board is shut down. Reseating the board will re-initialize
the board.
3. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Description/Recommendation
Continued on next page