Avaya Definity SI Maintenance Manual page 1193

Table of Contents

Advertisement

CLAN-BD (Control LAN Circuit Pack)
Table 10-151. TEST #598 Packet Interface Test — Continued
Error
Code
Result
2012
ABORT
2100
ABORT
FAIL
PASS
Congestion Query Test (#600)
This non-destructive test queries the number of used buffers to determine if the
CLAN circuit pack is congested.
If:
Used buffers are, or are
nearly, exhausted,
The test fails,
Normal call handling resumes when the CLAN circuit pack has recovered from
congestion.
555-233-123
Test
Could not allocate the necessary system resources to run test.
Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
Circuit pack has detected a failure of the Packet Interface Test
(#598).
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
UUCSS).
3. If the test continues to fail, replace the circuit pack.
The Packet Interface Test (#598) passed.
Then:
The test fails
The switch redirects outgoing calls to another available
CLAN, and denies new incoming calls
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-407

Advertisement

Table of Contents
loading