ETH-PT (Control LAN Ethernet)
Error Log Entries and Test to Clear Value
Table 10-278. ETH-PT Error Log Entries
Aux
Error Type
Data
1
0
0
1 (a)
0
513 (b)
0
769 (c)
0
1281 (d)
0
1537, 1538
(e)
1793-1920
(f)
2305-2560
(g)
2561-2816
(g)
3329 (h)
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. Error Type 1: Ethernet Local Looparound Test (#1278) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to repair procedures for Test #1278.
b. Error Type 513: Link Integrity Inquiry Test (#1282) failed or CLAN port
detected loss of Ethernet link integrity.
Possible causes:
1. Test the port (test port UUCSSpp long).
2. If the Link Integrity Inquiry Test (#1282) fils, refer to its repair
555-233-123
Associated Test
Any
Any
Ethernet Local
MINOR
Looparound
Test (#1278)
Link Integrity Inquiry
MINOR
(#1282)
WNG
Session Status Test
MINOR
(#1286)
TCP/IP Ping Test
WNG
(#1281)
Cabling
Ethernet transceiver
procedure.
Alarm
On/Off
Level
Board
Any
test port UUCSSpp s
ON
test port UUCSSpp l r 3
OFF
test port UUCSSpp r 2
OFF
OFF
OFF
Continued on next page