Avaya Definity SI Maintenance Manual page 1299

Table of Contents

Advertisement

DAT-LINE (Data Line)
Table 10-189. TEST #171 Digital Loop Around Test — Continued
Error
Code
2000
2003
2004
2005
2100
555-233-123
Test
Result
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
2. If the test continues to abort, escalate the problem.
ABORT
Failed to receive an off-hook from the Data Line.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
Failed to receive an off-hook from the Network Control Data
Channel.
ABORT
The handshake between the data channel and the data line
port failed.
1. Look for DATA-CHL errors in the Error Log. If present,
refer to DATA-BD (Network Control Circuit Pack)
Maintenance documentation.
2. Retry the command at 1-minute intervals a maximum of 5
times.
3. If the test still aborts, replace the circuit pack.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-513

Advertisement

Table of Contents
loading

Table of Contents