Maintenance Object Repair Procedures
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Tone Detection
Verification Test, for example, you may also clear errors generated from other
tests in the testing sequence.
Order of Investigation
Tone Detection Verification Test (#42)
Tone Detector Audit/Update Test (#43)
1
D = Destructive; ND = Nondestructive
Tone Detection Verification Test (#42)
This test verifies the "touch-tone digits detection" capability of the DTMR port is
functioning properly.
Table 10-253. TEST #42 Tone Detection Verification Test
Error
Code
none
1
1001
1002
10-698
Issue 4 May 2002
Test
Result
ABORT
The system was not able to allocate all the resources needed
for this test or there was an Internal System Error.
ABORT
The system could not allocate all the resources needed to test
the DTMR port.
ABORT
The system was unable to put the DTMR port in the
appropriate mode to test it.
ABORT
The system could not allocate time slots for the test
connection. This could happen when the system is heavily
loaded. If the system is not heavily loaded, then test the TDM
Bus via the test tdm [a|b] command. Refer to the TDM-BUS
(TDM Bus) Maintenance documentation for details.
1. Retry the command at one-minute intervals a maximum of
5 times.
Short Test
Long Test
Sequence
Sequence
X
X
Description/Recommendation
Continued on next page
1
D/ND
X
ND
X
ND
555-233-123