Maintenance Object Repair Procedures
Table 10-241. TEST #144 Slip Alarm Inquiry Test — Continued
Error
Code
Test Result
2000
ABORT
10-656
Issue 4 May 2002
Description/Recommendation
Response to the test was not received within the allowable
time period. This may be due to hyperactivity. Error type 1538
in the error log indicates hyperactivity. The hyperactive circuit
pack is out of service and one or more of the following
symptoms may be exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning
a no board result.
3. A busyout or a release command has no affect on the
test results.
4. A list config command shows that the circuit pack and
the ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated
from the system, and all of the trunks for this circuit
pack are placed into the out of service state. The
system will try to restore the circuit pack within 15
minutes. When no faults are detected for 15 minutes,
the DS1 interface circuit pack is restored to normal
operation. All of the trunks for the DS1 interface circuit
pack are then returned to the in service state.
Hyperactivity is often caused by the associated facility.
In such a case, faults (such as slips, misframes, or blue
alarms) would be entered in the error log. In addition,
many hardware errors would be logged against the
associated trunk circuits. If the facility is OK and the
error occurs again after 15 minutes, escalate this
problem.
Continued on next page