Avaya Definity SI Maintenance Manual page 1056

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Hardware Error Log Entries and Test to Clear
Values
Table 10-108. ISDN-BRI Port Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1 (a)
(a)
Level 1 Status
Inquiry (#621)
18
busyout port
PCSSpp
130 (b)
257 (c)
(c)
EPF Inquiry
(#622)
513 (d)
(d)
none
769 (e)
0
none
1281 (f)
NPE
Crosstalk
(#617)
1537 (g)
46210
CRC Error
Counter
(#623)
1793 (h)
BRI Port
Local TDM
Loop Around
(#619)
3841 (i)
46208
None
3842 (j)
0
None
3843 (k)
0
None
3844 (l)
46223
None
10-270
Issue 4 May 2002
Alarm
Associated
Level
Test
BRI-PORT
Any
WRN
WRN
WRN
WRN
(d)
WRN
MIN/ WRN
WRN
MIN/ WRN
Alarm Level
ABRI-PORT
ATT-PORT
On/
LGATE-POR
Off
T ATTE-PT
Board
Any
Any
MAJ/MIN/
OFF
2
WRN
OFF
ON
MAJ/MIN/
OFF
2
WRN
(d)
ON
MAJ
OFF
2
ON
MAJ/MIN/
OFF
2
WRN
2
ON
Continued on next page
Test to Clear
Value
test port
PCSSpp sh r 1
test port
PCSSpp sh r 2
release port
PCSSpp
test port PCSS
sh
test port
PCSSpp sh r 1
test port
PCSSpp l r 2
test port
PCSSpp l r 2
555-233-123