DIOD-TRK (DIOD Trunk) [G1.2SE]
Loop Around and Conference Circuit Test (#33)
This test checks the reflective loop and conference abilities of a CO port circuit.
The test uses 404 Hz, 1004 Hz, and 2804 Hz tones. Each tone is transmitted
separately through the loop and checked.
Table 10-226. TEST #33 Loop Around and Conference Circuit Test
Error
Code
7
1000
1004
2100
555-233-123
Test
Result
ABORT
Could not allocate system resources to run this test.
ABORT
Conference Circuit Test aborted.
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of 5 times.
ABORT
The port has been seized by a user for a valid call. Use the
status trunk command to determine when the port is available
for testing.
1. Retry the command at one-minute intervals a maximum of
5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
Description/Recommendation
Continued on next page