BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Table 10-108. ISDN-BRI Port Error Log Entries — Continued
Error
Aux
Type
Data
3845 (m)
None
3846 (n)
TEI
None
3847 (o)
0
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description, and follow the recommended procedures.
2
Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value
used in the set options command.
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The aux
data field contains one of the following values:
Refer to the repair procedures for Test #621.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, replace or
reinsert the circuit pack.
c. This error occurs when the EPF Status Inquiry fails due to an overcurrent
condition or when the BRI-LINE circuit pack detects that the EPF is in an
over current condition. The aux data field contains one of the following
values:
Execute the Short Test Sequence and see the repair procedures for Test
#622.
555-233-123
Alarm
Associated
Level
Test
BRI-PORT
blank - this indicates that the Level 1 Status Inquiry failed.
32773 - this is a message from the BRI-LINE circuit pack indicating
Level 1 has been deactivated.
blank - this indicates that the EPF Status Inquiry failed due to an
overcurrent condition.
40988 - this indicates that the BRI-LINE circuit pack has detected an
overcurrent condition and has turned the EPF off.
Alarm Level
ABRI-PORT
ATT-PORT
On/
LGATE-POR
Off
T ATTE-PT
Board
Continued on next page
Issue 4 May 2002
Test to Clear
Value
10-271