Avaya Definity SI Maintenance Manual page 1210

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-159. TEST #6 NPE Crosstalk Test — Continued
Error
Code
1004
1020
2000
2100
2053
10-424
Issue 4 May 2002
Test
Result
ABORT
The port was seized by a user for a valid call. Use the display
port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1-minute
intervals for a maximum of 5 times.
ABORT
The test did not run due to a previously existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or
the circuit pack and attempt to diagnose the already
existing error.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
At least one of the following errors was found on the DS1
circuit pack: loss of signal (1281), blue alarm (1793), red alarm
(2049), yellow alarm (2305), or hyperactivity (1537).
1. Look for the above error types in the Hardware Error Log
and follow the procedures given in the appropriate
DS1-BD or UDS1-BD maintenance documentation for the
listed error types.
Description/Recommendation
Continued on next page