Avaya Definity SI Maintenance Manual page 898

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Error log entries and test to clear values
Table 10-37. Analog line error log entries
Error
Aux
Type
Data
1
0
0
1(a)
40960
40975
40977
15(b)
Any
18
0
130(c)
257(d)
40973
513(e)
769
1025
1281
1537
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
Notes:
a. Error Type 1: these are in-line errors and can only be resolved over time.
10-112
Issue 4 May 2002
Associated
Alarm
Test
Level
Any
Any
none
Audits and
Updates Test
(#36)
busy station
WRN
extension
None
WRN
none
Station
WRN
Present Test
(#48)
Battery Feed
MIN/
2
Test (#35)
WRN
Looparound
MIN/
2
Test (#161)
WRN
Conference
MIN/
2
Test (#7)
WRN
NPE
MIN/
2
Crosstalk
WRN
Test (#6)
Aux Data 40960 indicates that too many simultaneous incoming
ringing attempts were made on this board. Only 4 ports on a board
may ring simultaneously. A 5th incoming call will cause an inline
error from the board.
Aux Data 40975 indicates that the terminal equipment was on-hook
when ring-tip was detected during ringing. This usually indicates a
failure in the terminal equipment or the type of terminal has a low
ringer impedance.
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
ON
release station extension
ON
test port UUCSSpp sh
OFF
test port UUCSSpp sh r 2
ON
test port UUCSSpp sh r 2
ON
test port UUCSSpp l r 2
ON
test port UUCSSpp l r 2
ON
test port UUCSSpp l r 2
555-233-123