Maintenance Object Repair Procedures
Table 10-160. TEST #7 Conference Circuit Test — Continued
Error
Code
0
10-430
Issue 4 May 2002
Test
Result
NO
The test could not relate the internal ID to the port (no board).
BOARD
This result could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, an insane board is
inserted, or the board is hyperactive (see note below).
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems
that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID
and the port. If this is not the case, dispatch to check to ensure
that there is a valid board inserted.
NOTE:
Hyperactivity causes some special problems with the
sequence suggested above.If the ports are translated
after issuing the list config command but the 'Vintage'
field reports that there is no board (when there really is a
board), then the busyout board and the release busy
board commands will not work (even though the reset
board command will work). The software will put the
hyperactive board back in service after the hyperactivity
clears.
Description/Recommendation
Continued on next page