Avaya Definity SI Maintenance Manual page 1028

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-95. TEST #50 Connection Audit Test
Error
Code
Result
None
ABORT
2100
1019
ABORT
FAIL
PASS
0
NO
BOARD
Control Channel Loop Test (#52)
The nondestructive Control Channel Loop Test is part of the maintenance
subsystem's Common Port Board Testing feature. The Common Port Board test
sends board vintage queries to a port circuit pack and checks the responses.
CCMS downlink notifications tell the circuit pack which TDM Bus (A or B) carries
the control channel and which carries the touch tones.
The test passes if the port circuit pack responds. The test aborts if the circuit pack
does not respond. The test fails otherwise.
10-242
Issue 4 May 2002
Test
System resources required for this test are not available.
Retry the command up to 5 times at 1-minute intervals.
The test aborted because a test was already running on the port.
Retry the command up to 5 times at 1-minute intervals.
Internal system error
Retry the command up to 5 times at 1-minute intervals.
The circuit pack has been updated with its translation.
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
Check the board translations.
If the ATM-TRK circuit pack is not administered, run add atm
trunk UUCSS.
If the ATM-TRK circuit pack is administered correctly, check the
error log.
If ATM-TRK circuit pack is hyperactive, shut down, and reseat
the circuit pack to force re-initialization.
If the ATM-TRK circuit pack is correctly inserted, run busyout
board.
Run reset board.
Run release busy board.
Run test board long to re-establish the linkage between the
internal ID and the port.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading