Exp-Link (Expansion Interface Link) - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

EXP-LINK (Expansion Interface Link)

EXP-LINK (Expansion Interface Link)
MO Name (in
Alarm Log)
EXP-LINK
1
Display errors for "infc" category and investigate EXP-INTF errors.
The EXP-LINK (Expansion Interface Link) Maintenance strategy is covered in the
EXP-INTF (Expansion Interface Circuit Pack) Maintenance documentation.
Error Log Entries and Test to Clear Values
Table 10-297. Expansion Interface Circuit Pack Error Log Entries
Error Type
Aux Data
0
0
122 (a)
122 (b)
None, 1-10
122 (c)
30-40
122 (d)
6
122 (e)
8
Notes:
a. This alarm is used only to indicate that all Expansion Interface Links
between a pair of Port Networks (PNs) are down. This condition is
indicated by the EXP-LINK Error Type 122 in the Error Log. When this
condition occurs, examine all EXP-INTF errors to resolve the alarm.
The pair of PNs is specified in the port fields as follows: 1-2 (PPN to
EPN1), 1-3 (PPN to EPN2), and 2-3 (EPN1 to EPN2).
b. Aux Data values of blank and 1 through 10 mean that the link is down due
to a defective Expansion Interface Link. Look for and resolve Expansion
Interface circuit pack errors.
c. Aux Data values of 30 through 40 mean that the EPN was reset because of
a temporary loss of system timing reference on the EPN. Execute the
display errors command with the category "tone" to determine what
caused the loss or restoration of the clock.
555-233-123
Alarm
Initial Command
Level
to Run
MAJOR
display errors
Alarm
Associated Test
Level
Any
Any
None
MAJOR
None
MAJOR
None
MAJOR
None
MAJOR
None
MAJOR
Full Name of MO
1
Expansion Interface Link
On/Off
Board
Test to Clear Value
Any
disp err
ON
ON
ON
ON
ON
Issue 4 May 2002
10-815

Advertisement

Table of Contents
loading