Maintenance Object Repair Procedures
Table 10-20. TEST #35 Battery Feed Test — Continued
Error
Code
0
10-54
Issue 4 May 2002
Test
Result
PASS
The port's battery feed chip is able to provide power to the
station equipment to detect on-/off-hook, but may not be able
to supply power for touch-tones. If touch-tones are inoperative
on this station, then replace the circuit pack because this port
is inoperative. User-reported troubles on this port should be
investigated by using other port tests, by examining station
wiring, or by examining the station.
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, check to ensure that there is a
valid board inserted.
Description/Recommendation
Continued on next page