CUST-ALM (Customer-Provided Alarming Device)
Table 10-173. TEST #115 Customer-Provided Alarming Device Test
Error
Code
(blank)
1000
2029
555-233-123
Test
Result
ABORT
Internal system error
1. Try the command at 1-minute intervals a maximum of 5
times.
PASS
The switch software successfully sent the request to the
Maintenance/Tape Processor or EPN Maintenance circuit
pack to turn on the CPAD. The CPAD must be physically
inspected to verify that it is working. If the CPAD is working
and the customer has complained that the CPAD did not
indicate a system alarm when it occurred, then check the
administered levels for turning on the CPAD via the Display
System-Parameter Maintenance screen form. Compare these
levels with the customer's specifications. If Test #115 passes,
and the CPAD is not being activated, check the connection of
the CPAD to the Maintenance/Tape Processor or EPN
Maintenance circuit pack. If the CPAD can be activated but
cannot be deactivated, first check to make sure Emergency
Transfer is not activated in the affected port network via the
status system command. Emergency Transfer can be forced
to manual OFF by the Emergency Transfer switch on the
Maintenance/Tape Processor or EPN Maintenance circuit
pack. If Emergency Transfer is OFF and the CPAD still cannot
be deactivated, check the administered levels for the CPAD
via the Display System-Parameter Maintenance screen form
and compare against the alarm levels currently present in the
system (display alarms command).