AN-LN-PT (Analog Line Port)
b. Error Type 15: this is a software audit error that does not indicate any
hardware malfunction.
1. Run the Short Test Sequence and investigate any associated errors.
c. Error Type 130: this error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes.
1. To clear the error, reseat or replace the circuit pack.
d. Error Type 257: this is an in-line error and can only be resolved over time.
This error indicates that ringing voltage is absent.
1. If only 1 analog circuit pack in the system has this problem, replace
2. If only analog circuit packs on a particular carrier have this error, the
3. If analog circuit packs on many carriers have this error, it is probably
e. Error Type 513:Test #48 can cause some terminal equipment to ring
briefly during daily maintenance.
1. If this disturbs the customer or the terminal equipment, disable it by
555-233-123
1. Call the terminal equipment and verify that the terminal rings.
2. If the terminal does not ring, then replace it.
3. Otherwise, issue the test port UUCSSpp command, and
follow the procedure for Test #48.
40977 indicates that no terminal equipment was connected when
ringing was attempted.
1. Run the short test via the test port UUCSSpp command, and
follow the procedure for the results of Test #48.
the circuit pack.
ringing generator may not be connected to this carrier.
a problem with the ringing generator.
setting the Tests field on the change station extension form to n.
On some software releases, this also disables Tests #6, 7, 161, and
35.
Issue 4 May 2002
10-113