Avaya Definity SI Maintenance Manual page 1097

Table of Contents

Advertisement

BRI-SET, ASAI-ADJ, BRI-DAT
Table 10-123. TEST #627 BRI Remote Loop Back — Continued
Error
Code
1187
2012
2068
555-233-123
Test
Result
ABORT
The circuit pack, port or station may have been busied out by a
technician.
1. Look in the Error Log for Error Type 18 (busied out) for
BRI-BD, BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release
the station via the release station command.
a. If this error type is present for BRI-PORT and BRI-SET,
then release the port via release port PCSSpp
command and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and
BRI-SET, then release the circuit pack via the release
port PCSSpp command and run the test again. If the
error is present for both BRI-BD and BRI-PORT, then
release the circuit pack via the release board PPCSS
command and run the test again. If the error is present
for BRI-SET only, then release the circuit pack via the
release port PPCSS command and run the test again.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
The endpoint has rejected the switch sent application
message. This indicates that the endpoint does not support
the ISDN-BRI Management and Maintenance Procedure for
Loop Back Testing.
1. Use the change station extension command and
change the MIMs Supported field to "no."
Description/Recommendation
NOTE:
When you release the circuit pack, you
release all ports associated with it. If certain
ports still need to be busied out, use the
release port PCSSpp command to busy
them out.