Maintenance Object Repair Procedures
Table 10-293. TEST #242 Expansion Interface Lightwave
Error
Code
2000
2100
2060
2500
1
10-794
Issue 4 May 2002
Transceiver Loop Around Test — Continued
Test
Result
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
The link on the Packet Bus being used to perform the test has
failed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, check for problems with the
Packet Control circuit pack (look for PKT-CTL errors).
ABORT
An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The test did not detect the test tone through the loop around
connection.
NOTE:
If the circuit pack is a TN570, the packet portion of this
test was not run since the circuit portion failed.
1. Test the Active Tone-Clock on the Port Network that
contains the defective Expansion Interface circuit pack to
verify that dial tone is being supplied.
2. If the Tone-Clock is healthy, issue the test board PCSS
long command on the Expansion Interface circuit pack.
3. If this test continues to fail, replace the Expansion
Interface circuit pack or transceiver. Then, reissue the test
board PCSS long command on the new Expansion
Interface circuit pack.
Description/Recommendation
Continued on next page