Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 10-190. Single-Carrier Cabinet Power Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
513
0
Single-Carrier Cabinet
Power Query Test (#79)
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following table. By clearing
error codes associated with the Single-Carrier Cabinet Power Query Test, for
example, you may also clear errors generated from other tests in the testing
sequence. Test descriptions and recommended maintenance procedures follow
for all errors that can occur during system technician-demanded testing.
Order of Investigation
Single-Carrier Cabinet Power Query Test (#79)
Emergency Transfer Query Test (#124) (a)
External Alarm Lead Query Test (#120) (b)
Analog Ring Generator Initialization Test (#117) (c)
Analog Ring Generator Query Test (#118) (c)
1
D = Destructive; ND = Nondestructive
Notes:
a. Refer to "EMG-XFER" for a description of this test.
b. Refer to "EXT-DEV" for a description of this test.
c. Refer to "RING-GEN" for a description of this test.
NOTE:
Tests #117 and #118 only show up in the test sequence if there is a TN768
Tone-Clock circuit pack in the port network being tested.
10-516
Issue 4 May 2002
Associated Test
Any
MAJOR
Alarm
On/Off
Level
Board
Test to Clear Value
Any
test environment P sh r 1
ON
test environment P r 2
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
1
D/ND
ND
ND
ND
ND
ND
555-233-123