ETH-PT (Control LAN Ethernet)
Table 10-283. TEST #1286 Session Status Test — Continued
Error
Code
1
FAIL
2
FAIL
PASS
555-233-123
Test
Result
System software indicates at least one Ethernet link session is
down (SOME UP).
1. Isolate downed sessions (status port UUCSSpp or status
link n).
2. Follow actions based on session information.
System software indicates all Ethernet sessions are down (ALL
DOWN).
1. Test the port (test port UUCSSpp) to verify the Ethernet
Local Looparound Test (#1278) result.
2. If test passes, wait for system software to indicate ALL UP.
3. If the test fails, check the destination and other components
in the path.
4. If the destination and other components in the path are
in-service, take action based on session information.
All sessions are up.
Description/Recommendation
Continued on next page
Issue 4 May 2002