Table 10-170. TEST #844-848 Transmission Test — Continued
Error
Code
1915
1918
1919
1920
1921
1922
1923
1924
1938
1939
1940
1941
10-462
Issue 4 May 2002
Test
Result
ABORT
Busy tone detected from far end.
1. Since the test line at the far end was busy. Try the test
again.
2. If the test continues to abort, the problem is with the far
end system.
ABORT
Test progress tone not removed from far end (type 105 test line
only).
1. The problem is with the far end system; a technician at the
far end should test the test line (TN771 or ADFTC).
ABORT
Unexpected far end release
1. The problem is with the far end system; a technician at the
far end should test the test line (TN771 or ADFTC).
ABORT
No response from far end.
1. The problem is with the far end system; a technician at the
far end should test the test line (TN771 or ADFTC).
ABORT
No data returned from far end.
1. The problem is with the far end system; a technician at the
far end should test the test line (TN771 or ADFTC).
ABORT
Steady, unidentifiable tone from far end
1. See actions for error code 1905.
ABORT
Broadband energy detected from far end (such as voice or
announcement).
1. See actions for error code 1905.
ABORT
No test tone from far end
1. See actions for error code 1905.
ABORT
Near-end self test failed.
1. Test the TN771 circuit packs.
ABORT
Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN771 circuit packs.
ABORT
Far end noise self check failed.
1. The problem is with the far end system; a technician at the
far end should test the test line (TN771 or ADFTC).
ABORT
High frequency singing return loss self check failed.
1. Test the TN771 circuit packs.
Description/Recommendation
Continued on next page