Avaya Definity SI Maintenance Manual page 1462

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-247. TEST #1212 CPE Loopback Jack Test — Continued
Error
Test
Code
Result
1005
ABORT
1015
ABORT
1039
ABORT
1950
ABORT
ABORT
2100
ABORT
10-676
Issue 4 May 2002
Description/Recommendation
CPE Loopback Jack Test cannot be executed in the current
configuration. To run this Test, the TN767E or later suffix DS1 must
be administered for 24-channel operation. The "Bit Rate" field on
the DS1 circuit pack administration form must be set to "1.544" for
24-channel operation.
Ports on the DS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put all trunks or
ports of the DS1 Interface circuit pack into the out-of-service
state.
2. Retry the command.
The DS1 Interface circuit pack is providing timing for the system.
Executing this test could cause major system disruption.
If the DS1 Interface circuit pack needs to be tested, set the
synchronization reference to another DS1 Interface circuit pack or
to the Tone-Clock circuit pack via the following command
sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
Another loopback/span test is already executing on the DS1 board
or the board is in a network requested loopback mode (Line
loopback or Payload loopback). The hardware error log will indicate
whether a Customer Loopback Jack Test, Far CSU Loopback Test,
or the One-Way Span Test is executing or if the board is in line
loopback or payload loopback mode. Only one long-duration
loopback/span test can be active at a given time. Thus, if a
loopback/span test is already active, that test must be terminated
via the test ds1-loop UUCSS end-loopback/span-test command in
order to execute this test.
Internal system error
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5
times.