Avaya Definity SI Maintenance Manual page 823

Table of Contents

Advertisement

ADX16A-PT (AUDIX Analog Line/Control Link)
Table 10-14. TEST #6 NPE Crosstalk Test
Error
Code
1000
1001
1002
1003
555-233-123
Test
Result
ABORT
Could not allocate the necessary system resources for this
test. Try (a).
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for certain tests. Wait until the port is idle
before testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
ABORT
Could not allocate the necessary system resources to run this
test. Try (a).
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS Maintenance documentation to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, retry the command at 1-minute intervals a
maximum of 5 times.
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Resolve any "TTR-LEV" errors.
2. Resolve any "TONE-PT" errors.
3. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-37

Advertisement

Table of Contents
loading

Table of Contents