Avaya Definity SI Maintenance Manual page 1586

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-295. TEST #336 Expansion Interface Reset Test
Error
Code
4
1015
2000
2100
9999
12000
12100
10-800
Issue 4 May 2002
Test
Result
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
Could not reset EPN Expansion Interface circuit pack over
optical fiber since PPN Expansion Interface circuit pack on
opposite end of fiber is not inserted.
1. Insert opposite Expansion Interface circuit pack and
perform reset again.
ABORT
The system does not allow this test to be run because the
Expansion Interface circuit pack has not been busied out.
1. Busyout the Expansion Interface circuit pack. Repeat the
reset board PCSS command.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
Expansion Interface circuit pack reset successfully. Could not
perform initialization test results query because link to EPN is
not up.
1. Execute release board PCSS. Wait one minute. Issue the
display error command. If you see Error Type 2049
logged against this Expansion Interface circuit pack, then
the Expansion Interface Reset Test has failed with an error
code equal to the aux data of this entry. Otherwise, the
initialization tests have passed.
ABORT
Expansion Interface circuit pack reset successfully. Response
to the initialization test results query was not received within
the allowable time period.
ABORT
Expansion Interface circuit pack reset successfully. System
resources required to run initialization test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading