CLSFY-PT (Call Classifier Port)
Table 10-155. TEST #42 Tone Detection Verification Test — Continued
Error
Code
2006
2000
2100
555-233-123
Test
Result
ABORT
This abort code indicates that the active Tone-Clock circuit
pack might not be functioning properly. If there is more than
one Tone Detector circuit pack in the system, then the
problem can be either with the Tone-Clock circuit pack or the
Tone Detector circuit pack. This could also be caused by the
companding mode administered for the system not matching
that of the Tone Detector circuit pack [G3iV2-386].
1. [G3iV2-386] Make sure that the companding mode of the
system matches that of the Tone Detector (TN748 for
Mu-law systems and TN420 for A-law systems).
2. Test the active Tone-Clock circuit pack in the port
network. This test is being executed via the test
tone-clock qualifier system technician command.
("qualifier" is the carrier of the active Tone-Clock circuit
pack to be tested. Valid qualifiers are: a, b, 1a, 1b, 2a, and
2b.) Refer to the TONE-BD (Tone-Clock Circuit Pack)
Maintenance documentation for details.
3. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-415