Maintenance Object Repair Procedures
Table 10-224. TEST #0 Dial Tone Test — Continued
Error
Code
1018
1005
2000
2002
1009
10-602
Issue 4 May 2002
Test
Result
ABORT
Test has been disabled via administration.
1. Verify that the "Maintenance Tests?" field on the Trunk
Group Form is set to "n." To enable the test, issue the
change trunk-group x command where "x" equals the
number of the trunk group to be tested. Then change the
entry in the "Maintenance Tests?" field on the form to "y."
ABORT
Trunk has been administered as incoming-only; or DID trunk
group type; dial tone can only be obtained on outgoing trunks.
This is a normal condition.
ABORT
Response to the test was not received within the allowable time
period.
1. Retry the command at one-minute intervals a maximum of
5 times.
FAIL
Trunk was seized, but dial tone could not be detected.
1. Check for errors on TONE-BD or TONE-PT. Clear any
errors found and repeat test.
2. If error has still not cleared, refer problem to CO.
FAIL
Seizure portion of test failed due to hardware problem. Fault is
usually caused by a disconnected trunk.
1. Check trunk wiring to ensure good connection; repeat test
if wiring correction made.
2. Locate another identical CO trunk and swap its wiring with
one under test. Repeat test on both trunks and determine if
problem follows trunk or remains at original port. If problem
follows trunk, refer problem to CO. If problem remains at
port, replace circuit pack and repeat test.
3. If replacing circuit pack does not clear failure, escalate the
problem.
PASS
Detected tone was not pure dial tone. No action required.
PASS
Trunk was seized, and dial tone was detected. User-reported
troubles on this port should be investigated by using other port
tests and by examining trunk or external wiring.
Description/Recommendation
Continued on next page
555-233-123