Maintenance Object Repair Procedures
o. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status Test
(#601) failed. This failure may be due to:
If:
RSCL disconnects at link level
Link cannot be reconnected quickly
p. Error Type 3330: Critical failure in Packet Bus interface.
Below, Error Types correspond to descriptions.
If the switch detects:
1 error,
2 errors in 15 minutes,
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
q. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that
reported threshold number of errors. One or more of the following
symptoms may be present:
If Error Type 3999:
Does not accompany
Error Type 3586,
Does not accompany
Error Type 3586,
Accompanies Error
Type 3586,
10-398
Issue 4 May 2002
This circuit pack
The packet bus
The packet interface circuit pack.
Then it:
Resets circuit pack.
Raises MINOR alarm.
Circuit pack port tests return NO BOARD.
List configuration command shows circuit pack and ports are
installed properly
And traffic
volume is:
Heavy
Light
Either Light or
Heavy
Then:
Link fails
Switch raises MINOR alarm
Then:
Circuit pack is in service, but sent
at least half hyperactive
threshold. With heavy traffic, this
is normal.
Circuit pack is in service, but sent
at least half hyperactive
threshold. With light traffic, this
error indicates a problem with the
circuit pack, its links, or the
equipment attached to the links.
Switch removed hyperactive
circuit pack.