Avaya Definity SI Maintenance Manual page 1524

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Hardware Error Log Entries and Test to Clear
Values
Table 10-277. EPN-SNTY Error Log Entries
Error
Aux
Type
Data
1
0
0
8801 (a)
Any
8802 (b)
Any
8803 (c)
Any
8804 (d)
Any
9901 (e)
Any
9902 (f)
Any
9903 (g)
Any
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This error occurs whenever the EPN is unable to send up-link control
messages and the control channel of the TDM Bus in the EPN has been
switched as part of the recovery procedure.
b. This error occurs whenever the EPN is unable to send up-link control
messages, and an EI link switch is invoked as part of the recovery
procedure.
c. This error occurs whenever the EPN is unable to send up-link control
messages and the EPN Tone-Clock is switched as part of the recovery
procedure.
d. This error occurs whenever the EPN is unable to send up-link control
messages and the EPN has been reset as part of the recovery procedure.
e. This error occurs whenever the EPN is unable to send up-link control
messages, but recovers after the control channels of the TDM Bus in the
EPN are switched.
f. This error occurs whenever EPN is unable to send up-link control
messages, but recovers after the Expansion Interface Links to the EPN are
switched.
g. This error occurs whenever the EPN is unable to send up-link control
messages, but recovers after the active Tone-Clock in the EPN is switched.
10-738
Issue 4 May 2002
Associated Test
Any
None
None
None
None
None
None
None
Alarm
On/Off
Level
Board
Test to Clear Value
None
555-233-123

Advertisement

Table of Contents
loading