Avaya Definity SI Maintenance Manual page 1228

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-164. CO Trunk Errors with NO Tests — Continued
Error
Aux
Type
Data
257
50176
Battery reversal detected. This is usually
caused by the CO (often seen with
step-by-step and cross-bar offices in
connection with outgoing calls). This is
detected if the direction of the loop current
changes from normal to reverse for at least
40 msec. Could occur if the trunk was just
installed and for some reason the Tip and
Ring wires were reversed at the PBX. If
battery reversals occur during dialing, wrong
numbers may result. The CO should be
asked to remove the battery reversal option.
513
57364
Ground detector stuck active. After several
occurrences, an on-board minor alarm is
generated.
769
57392
CO not releasing after call is dropped from
PBX end (off-board alarm after several
occurrences), or the loop is not open after a
disconnect (on-board alarm after several
occurrences).
2561
57345
Single polarity ringing current. This error
results from abnormal ringing current, but
does not prevent the incoming call from
being accepted. One cause could be that the
reverse current detector associated with the
port is failing. (Will not be detected by any
tests.) Another cause could be that normal
current is not detected. In this case, neither
incoming nor outgoing calls can be
completed, and the dial tone test also fails.
The last cause could be that certain types of
noise are present on the CO line during the
silent period of ringing.
10-442
Issue 4 May 2002
Description and System Action
System Technician Action
Refer problem to CO.
Run short test. If test aborts
with Error Code 1000,
disconnect Tip and Ring and
repeat short test. If test still
aborts, replace circuit pack. If
test passes, refer problem to
CO. If any other error code is
received, pursue that problem.
For off-board alarm, refer
problem to CO. For on-board
alarm, the circuit pack has an
on-board problem (for
example, stuck relay) and
should be replaced.
Check for other errors first and
then see Note 4 at end of
table.